ZKTeco Comet-S1000 Swing Barrier Speed Gate

ZKTeco Comet-S1000 Swing Barrier Speed Gate

The ZKTeco Comet-S1000 is a single-lane indoor swing barrier speed gate designed for controlled pedestrian entry in corporate offices, commercial buildings, reception areas, campuses and other managed-access environments. Its slim cast-aluminium chassis, brushless motor, safety sensing and configurable credential options make it suitable for organizations that want a modern entrance lane integrated with an access control system. The standard lane width is 660 mm, with a 900 mm option for wider passage requirements, while supported authentication choices can include RFID, QR code, fingerprint and facial recognition depending on the selected configuration and controller. Buyers should confirm the credential method, lane width, controller, access software, floor preparation, barrier material and any facial-recognition mounting requirements before ordering. FourTeck supports businesses in Dubai and across the UAE with model selection, configuration review, quote preparation, delivery coordination and warranty guidance. Availability can vary by configuration, project quantity and supplier status. Contact FourTeck with your required number of lanes, user credential method, installation location and target deployment schedule to receive practical buying assistance and a suitable quotation.

SKU: ZKTECO-COMET-S1000-DUBAI Category:
Entrance Control / Swing Barrier

ZKTeco Comet-S1000 Swing Barrier Speed Gate in Dubai, UAE

A single-lane indoor speed gate for organizations that need controlled pedestrian access without turning the reception area into an industrial-looking checkpoint.

The Comet-S1000 combines swing-barrier movement, infrared presence sensing, a brushless drive system and flexible credential integration. It is intended for projects where the access lane, authentication method, safety behaviour and visual presentation all matter. FourTeck can help buyers translate those project requirements into a practical bill of materials before a quotation is prepared.

Single-Lane DesignMulti-Credential OptionsIndoor Deployment

Request QuoteReview Specifications

Verified product visual

ZKTeco Comet-S1000 swing barrier speed gate from the Comet Series

Quick product information
BrandZKTeco
ModelComet-S1000
Product typeSwing barrier speed gate
EnvironmentIndoor
AuthenticationRFID, QR, fingerprint or face options
AvailabilityContact FourTeck for current options
SupportConfiguration and quote guidance
WarrantyConfirm terms with final supply quotation
Product overview

A controlled entrance lane designed around both people flow and access decisions

The Comet-S1000 is best understood as the physical passage layer of an access-control project. It creates a defined pedestrian lane, receives the release decision from the chosen controller or credential system, moves the swing barrier to permit entry, and uses sensing logic to monitor the person moving through the lane. For a corporate reception, shared office, education facility, financial workplace or managed commercial building, that combination helps turn an ordinary doorway into a more structured entry point.

Its standard configuration provides a 660 mm passage, while a 900 mm lane can be selected where a wider route is needed. The gate uses a DC brushless motor with a stated movement time of 0.8 seconds for opening or closing. ZKTeco also specifies a mechanical clutch intended for anti-panic and anti-collision behaviour, infrared sensing, safety force detection, anti-intrusion logic, anti-tailgating logic, wrong-way alarms and automatic opening under emergency or power-loss conditions. These are important project details because entrance-control equipment has to balance restriction with safe movement rather than simply lock a path.

The authentication layer is intentionally flexible. Depending on the selected build, the lane can be prepared for RFID cards, QR codes, fingerprint readers, facial recognition or combinations of those methods. Under-mount and top-mount terminal approaches are supported, and the exact controller determines software compatibility. That means buyers should not purchase the lane body in isolation. The correct question is whether the selected gate, credential reader, controller, management platform, fire-alarm interface, lane width and installation environment work together as one entrance system.

For UAE buyers, this is especially relevant in projects where architects, facilities teams, security teams and IT administrators may all influence the specification. FourTeck can help consolidate those requirements into a clearer request: number of lanes, entry and exit logic, user credential, visitor handling, accessibility expectation, controller choice, software platform, floor condition, delivery point and required support. That preparation reduces the chance of buying a visually suitable gate that later needs different readers, mounting hardware or integration work than expected.

Business benefits

Why the Comet-S1000 can fit a professional access-control project

The strongest reason to consider this model is not a single specification. It is the way the lane design, safety features and credential flexibility can be combined around a controlled indoor entrance.

01 / ACCESS FLOW

A defined lane instead of an uncontrolled doorway

A speed gate makes the permission decision visible and physical. When a valid credential is presented, the barrier opens to create a clear passage; when entry is not authorized, the lane remains controlled. For offices, campuses and managed facilities, this supports a more consistent entry process than relying on staff observation alone. It can also create a more professional visitor experience when the credential workflow is planned well.

02 / FLEXIBILITY

Choose credentials around the operating model

RFID can suit employee access, QR can support visitor or temporary credentials, fingerprint can provide biometric verification, and facial recognition can support touchless workflows. The benefit is not simply having multiple technologies available; it is the ability to select a method that matches user volume, security policy, visitor process and existing access-control infrastructure.

03 / SAFETY

Sensing and emergency behaviour are part of the design

The official specifications include safety force sensing, infrared presence detection, emergency release behaviour and automatic opening on power loss. Those functions matter because pedestrian control equipment must react predictably when a person pauses, passes with assistance, moves in the wrong direction or an emergency state is triggered. Final site testing and system configuration remain important.

04 / DESIGN

Slim architecture for reception-facing spaces

With a standard chassis depth of only 115 mm and a cast-aluminium body, the Comet platform is designed for entrances where appearance matters. The tempered-glass lid, transparent barrier leaf options and configurable RGB indication can be easier to integrate into an architectural lobby than bulkier industrial gates. Site dimensions still need to be confirmed before ordering.

05 / MAINTENANCE

Brushless drive and service-oriented construction

ZKTeco specifies a DC brushless motor, a mean cycles between failures figure of six million and a mean time to repair under 60 minutes. These figures do not remove the need for preventive maintenance, but they give project planners useful reference points when evaluating an entrance lane that may operate repeatedly throughout the business day.

06 / PROJECT FIT

A wider passage option helps address accessibility planning

The 900 mm optional lane can be important where the project needs more space for wheelchairs, mobility assistance or easier movement with bags and equipment. ZKTeco also differentiates accessibility handling by authentication configuration, particularly for the under-mount facial-recognition version. Buyers should therefore treat accessibility as a complete lane-design question involving width, reader position, user detection and operating policy rather than selecting a wider barrier leaf alone.

Product highlights

What stands out technically

This model is built around a single swing lane, a slim cast-aluminium chassis and an access-control architecture that can be equipped for several credential types. The most important buying advantage is configurability: the entrance can be tailored to the organization instead of forcing every user through the same verification method.

The lane includes an internal buzzer and a customizable seven-colour RGB strip along the lid for visual status communication. ZKTeco identifies blue for standby, steady green for normal use, steady red for closing and flashing red for alarm conditions. Those cues can help users understand the lane state quickly in busy reception spaces.

MovementDC brushless motor with 0.8-second opening or closing movement time.
DetectionEight standard high-position infrared sensor pairs plus safety force sensing.
IntegrationFire-alarm relay input, RS485 communication and controller-dependent software support.
CredentialsRFID, QR, fingerprint and facial-recognition mounting options are available by configuration.
Technical specifications

Confirmed Comet-S1000 technical details

The values below are based on ZKTeco product information for the Comet Series. Credential hardware, controller, software connection, barrier material and lane width can change with the selected configuration, so the final quotation should identify the exact build.

Specification Comet-S1000
Brand / Model ZKTeco / Comet-S1000
Product type Single-lane swing barrier speed gate
Lane width 660 mm standard; 900 mm optional
Dimensions 1500 × 115 × 1000 mm standard
Motor DC brushless motor
Movement time 0.8 seconds per opening or closing movement
Movement accuracy ≤1.5 degree per movement
Chassis / lid Cast aluminium alloy chassis; black tempered-glass lid standard
Barrier leaf Clear acrylic standard; clear tempered glass option
IR sensors 8 pairs standard, high position
Credential options RFID, QR code, fingerprint, facial recognition and selected combinations; configuration dependent
Typical stated flow rates RFID 30/min; QR 30/min; fingerprint 20/min; face 15/min
Power supply 110 V / 220 V AC, 50–60 Hz
Power rating 20 VA standby; 120 VA operation
Communication / fire input RS485 ×1; fire-alarm relay input ×1
Software support ZKEasyGO, ZKBio Access or ZKBio CVSecurity depending on equipped controller
Operating environment Indoor
Temperature / humidity -28°C to 60°C; up to 95% RH non-condensing
Net / gross weight 100 kg net; 130 kg gross
MCBF / MTTR 6 million cycles / under 60 minutes
Certifications CE, FCC
Site preparation Flat, level finished floor; optional base plate for unfinished floor

The main purchase choices are not the motor or chassis dimensions; those are largely fixed. The choices that change the project are lane width, reader or biometric terminal, controller, software platform, barrier material and the arrangement of multiple lanes. A buyer planning employee access with existing RFID cards may need a different bill of materials from a reception that issues QR visitor passes or a site that wants face authentication. For that reason, confirm the end-to-end access workflow before locking the hardware list.

Configuration workbench

How to select the right Comet-S1000 configuration

The correct configuration starts with the way people will use the entrance. A clear requirement brief makes it easier to decide which reader, controller, lane width and software connection belong in the quotation.

01 / CONFIRM

Who is passing through?

Separate employees, contractors, visitors and assisted users. Their credentials and passage patterns may be different. If visitors receive QR codes while staff use RFID cards, specify both workflows from the beginning rather than adding a second reader later.

02 / MATCH

Which credential should release the lane?

Choose the authentication method around your access policy and existing system. RFID can be straightforward for staff cards; QR can suit temporary or visitor permissions; biometrics may help where identity verification must be tied more closely to the user. Reader model and mounting method are configuration dependent.

03 / HIGH RISK

Is the passage width suitable?

The standard 660 mm lane is compact, but not every project should default to it. If wheelchairs, mobility assistance, luggage or frequent equipment movement are expected, review the 900 mm option and the surrounding clearances. Accessibility should be checked against the complete entrance design and local project requirements.

04 / CHECK

What controller and software are already in use?

Software support depends on the equipped access controller. Tell FourTeck whether the project already uses a ZKTeco platform, another controller architecture or a new standalone deployment. Integration needs should be confirmed before equipment is ordered.

05 / PLAN

What happens during fire alarm or power loss?

The gate includes a voltage-free fire input and supports automatic opening when power is lost. The project should still document how the entrance behaves during emergency states, how that signal is wired, and who is responsible for commissioning and testing the fail-safe operation.

06 / REVIEW

Is the installation area ready?

ZKTeco specifies an indoor environment and a flat, level finished floor, with a base plate option for unfinished floors. Check power, cable routes, controller location, reception furniture, adjacent lanes, emergency egress and final floor finish before scheduling installation.

For a useful quote, send FourTeck the number of lanes, required passage width, preferred credential, expected daily users, current access platform, project location, floor condition, installation requirement, target date and any accessibility or visitor-management needs. That gives the sales team enough context to review whether the requested hardware is likely to fit the project.

Business use cases

Where this type of speed gate makes practical sense

The Comet platform is intended for indoor entrance control. It is most useful where the organization needs a clearly managed pedestrian lane and already has, or plans to build, a credential-based access process.

PRIMARY USE CASE

Corporate reception and employee access

A reception area often needs to do several jobs at once: allow employees to enter quickly, stop unverified access, direct visitors, preserve a clean architectural look and maintain a safe passage route. The slim Comet chassis and multiple credential options make it suitable for this kind of mixed environment. Staff may use cards or biometrics while visitors follow a separate QR or reception-assisted process, provided the controller and software are configured for that workflow.

Commercial buildings and shared offices

Multi-tenant buildings need an entrance layer that can separate public lobby space from controlled areas. A speed gate can provide the physical checkpoint while the access system decides which tenant, floor or zone a user may enter. The final software and access policy depend on the controller and wider building system.

Education and campus administration

Administrative buildings, libraries, staff areas or controlled student facilities may use turnstile-style entry where cards or another credential identify permitted users. The optional wider lane can also be considered where accessibility and varied user groups are part of the requirement.

Financial and professional workplaces

Organizations that maintain stricter front-of-house access policies can use a speed gate to enforce the release decision from the credential system. Anti-tailgating and wrong-way detection functions add behavioural monitoring at the lane, although overall security still depends on staffing, cameras, doors, policies and the surrounding access design.

Visitor-managed facilities

Where visitors are preregistered or issued a temporary credential, QR-capable configurations can help connect the visitor process to the physical lane. Before selecting this approach, confirm how QR codes are generated, where they are validated, how exceptions are handled and how reception staff intervene when a credential fails.

High-visibility lobbies

The cast-aluminium structure, glass lid and clear barrier materials can suit locations where the security equipment is part of the customer-facing interior. Buyers should still prioritize safe circulation, lane spacing and service access over appearance. Architectural drawings should be reviewed with the physical dimensions before finalizing the entrance plan.

Feature deep dive 1

Comet-S1000 Credential Flexibility and Access Integration

The gate can be configured around several credential technologies rather than being tied to one reader. ZKTeco lists under-mount support for RFID readers, QR readers, fingerprint readers and facial-recognition terminals, as well as top-mount options for selected face terminals. That creates useful design freedom, but it also means the buyer has to define the authentication experience before the hardware is finalized.

A staff-only entrance may prioritize fast card presentation and simple visual feedback. A visitor-heavy lobby may need QR handling. A higher-assurance area may combine a biometric decision with a card or another factor depending on the access-control design. The lane should therefore be treated as one component of a complete identity-and-access workflow, not a standalone security product.

Feature deep dive 2

Comet-S1000 Safety Sensing and Passage Behaviour

A speed gate has to do more than open quickly. It needs to understand where the person is in the lane, avoid closing at the wrong time, react to forced movement and enter a safe state when the building signals an emergency. ZKTeco specifies eight high-position infrared sensor pairs as standard, together with safety force sensing, lower safety sensors, presence detection, anti-intrusion logic, anti-tailgating logic and wrong-way alarms.

Normal passageSensors help track movement through the lane so the barrier can operate around the user rather than on a simple timer alone.
Forced movementA mechanical clutch is specified for anti-panic and anti-collision behaviour, reducing the risk of damage when the barrier is pushed.
Emergency stateA voltage-free fire input and automatic opening during power loss support fail-safe planning when integrated correctly.

These features should be commissioned as part of the whole entrance, not assumed to work correctly without configuration and testing. The installer should verify sensor alignment, barrier motion, fire input, power-loss response, accessibility behaviour and the interaction between adjacent lanes. Project teams should also decide how security staff respond to anti-tailgating or wrong-way alarms, because the gate can detect events but the building still needs an operating procedure.

Feature deep dive 3

Comet-S1000 Lane Design, Throughput and User Experience

The way a gate feels in daily use depends on more than opening speed. Lane width, credential speed, user familiarity, reader position, visitor exceptions and adjacent traffic all influence throughput. ZKTeco states up to 30 people per minute for RFID or QR, 20 for fingerprint and 15 for face in its Comet specifications. Those figures are useful references, but real flow will depend on the credential process and site behaviour.

Decision checklist

  • Use the standard 660 mm lane where compact layout is the priority and the passage requirement allows it.
  • Consider the 900 mm option where mobility devices, bags or wider passage are expected.
  • Do not compare throughput by motor speed alone; credential verification can be the slower part of the journey.
  • Place readers and displays where users can understand what to do before they enter the sensing zone.
  • Plan exception handling so reception staff can assist when a credential is rejected or a visitor is not preregistered.

For projects with several parallel lanes, the Comet-S1200 dual-wing extension model may be part of the arrangement, while the S1000 functions as the primary single-lane unit. The exact lane combination should be drawn on the floor plan before procurement. That is especially important in premium lobbies where security equipment, reception furniture, lift queues and visitor circulation all compete for the same space.

Buyer decision guide

What Buyers Should Check Before Purchase

The biggest purchase risk is choosing the gate body by model name and leaving the credential, controller, lane layout and installation details for later. A speed-gate project works best when those decisions are made together.

01 / FIT

Configuration Fit

Confirm whether the project needs RFID, QR, fingerprint, facial recognition or a combination. The answer changes reader hardware, mounting, controller requirements and user experience. Also confirm whether 660 mm is sufficient or whether a 900 mm lane is needed. If several lanes are planned, provide a sketch showing entry direction, exit direction and any wider accessible lane.

02 / MATCH

Compatibility Check

Tell the supplier which access controller, software platform and credentials are already deployed. ZKTeco software support depends on the equipped controller, so existing infrastructure can materially change the recommended configuration. Check fire-alarm integration, RS485 needs, power location, floor finish, reader cabling and the available space around each chassis before confirming the order.

03 / TERMS

Availability and Warranty

Availability can change with the selected reader, barrier material, lane width, project quantity and supplier status. Warranty terms may also depend on the supplied configuration and commercial source. Ask for the final quotation to identify the exact model, accessories, warranty guidance, delivery scope and any installation services rather than relying on a generic web listing.

04 / REQUEST

Quote Preparation

Provide the quantity of lanes, preferred credential, expected user volume, passage width, building location, access software, target date, installation requirement and any accessibility or visitor needs. If the project is replacing an older gate, include photos, current lane dimensions and controller details. Those inputs help FourTeck recommend a suitable supply scope instead of pricing an incomplete configuration.

Buyers should also plan the long-term operating details: who will issue credentials, who will manage visitor exceptions, how access logs will be reviewed, what preventive maintenance will be scheduled and how the entrance will be handled during renovation or power work. The gate may be the most visible part of the system, but the surrounding process determines whether it remains convenient and secure over time.

UAE service support

Selection, delivery coordination and warranty guidance

FourTeck supports product inquiries in Dubai and across the UAE with assistance around model selection, configuration review, quotation, delivery coordination and warranty guidance. For this type of entrance-control equipment, support is most useful before the purchase order is issued, because a small change in credential method or lane layout can change the required readers, controller, mounting hardware or software connection.

Selection supportReview lane width, credential method, controller and intended usage before pricing.
Delivery coordinationPlan delivery around project location, quantity, configuration and supplier availability.
Warranty guidanceConfirm applicable terms in the final commercial quotation and supply documentation.

Availability is not assumed to be immediate. It can vary with model configuration, project quantity and current sourcing conditions. For the fastest review, share the complete requirement rather than asking only whether the base model is available. Contact FourTeck for product assistance.

UAE city coverage

Support for projects across major UAE business centres

Businesses in Dubai, Abu Dhabi, Sharjah, Ajman and other UAE locations can contact FourTeck for product availability guidance, configuration review and quote assistance. The project location matters because delivery planning, installation access, site scheduling and after-sales handling may vary. When requesting a quotation, include the delivery site, floor or entrance location, number of lanes and whether installation or commissioning support is required. This helps the sales team distinguish a simple equipment supply from a project that needs more detailed coordination.

Regional inquiries

GCC and Africa project availability guidance

FourTeck also supports business technology inquiries through regional channels for selected GCC and Africa markets. Requirements from Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Kenya, Uganda and other locations can be reviewed based on product configuration, supplier status, shipping route and local project needs. Stock, delivery time, warranty handling and installation options should be confirmed for the destination rather than assumed from UAE availability.

Regional buyers can begin with FourTeck UAE, FourTeck Kenya, FourTeck Uganda, FourTeck Africa or FourTeck Kuwait as appropriate. Include the required lane count, credential method, destination and project schedule so the inquiry can be evaluated with the right context.

Related options

Other ZKTeco entrance-control options buyers may consider

A similar model may be more suitable when the lane arrangement, outdoor requirement, cabinet material or project budget is different. The alternatives below are starting points for discussion, not automatic replacements.

ZKTeco Comet-S1200

Designed as the dual-wing companion within the Comet Series, it is relevant when a project needs additional lane combinations built around the same design language. Confirm the exact arrangement with the project drawing.

Explore Comet-S1200 options →

ZKTeco Saturn-S1000

A different ZKTeco swing-barrier family that can be relevant where project environment, cabinet design or authentication approach calls for another platform.

View Saturn-S1000 related listings →

ZKTeco Mars-S1000

Worth reviewing for projects that want a different ZKTeco swing-gate construction and entrance-control profile. Compare environment, lane width and material requirements before choosing.

Review Mars-S1000 choices →

ZKTeco swing barrier range

If the project does not yet have a fixed model, browsing the broader swing-barrier range can help identify a better fit for lane count, environment or physical design.

Browse ZKTeco swing barriers →

Access control readers and terminals

The correct reader or biometric terminal is part of the complete gate solution. Match the credential hardware to the controller and management software.

Explore ZKTeco access-control products →

FourTeck support approach

Why business buyers involve FourTeck before ordering

Entrance-control purchases often cross several teams. Security defines who may enter. IT or the system integrator manages credentials and software. Facilities manages power, floor work and physical access. Procurement needs a clear commercial scope. FourTeck can help bring those details into one product inquiry so the buyer is comparing a complete requirement rather than only a chassis model.

01 / Product sourcing supportReview current supply options against the requested model and configuration.
02 / Configuration guidanceCheck lane width, credential, controller and deployment assumptions before quotation.
03 / Quote assistanceTurn a project brief into a clearer commercial request with fewer missing items.
04 / Delivery coordinationPlan around quantity, configuration, destination and project schedule.
05 / Warranty guidanceClarify the applicable commercial terms for the final supplied configuration.
06 / Alternative matchingConsider another ZKTeco gate family when environment or layout makes it a better fit.

This approach is especially useful for project quantities, fit-out schedules and replacement projects where site constraints may not be visible from a model number. The goal is to identify the information that changes the purchase decision early, so the quotation is more useful to both technical and procurement teams.

Frequently asked questions

Questions business buyers commonly ask

01

What is the ZKTeco Comet-S1000 used for?

It is a single-lane indoor swing barrier speed gate used to control pedestrian entry. A connected access-control system decides whether a presented credential is valid, and the gate creates the physical passage. It can suit offices, commercial buildings, campuses and managed reception areas where staff, visitors or other authorized users need a structured entrance process.

02

Which credential methods can be configured?

ZKTeco lists options for RFID cards, QR codes, fingerprint readers and facial-recognition terminals, including selected combinations. The exact reader and mounting approach depend on the chosen configuration. Buyers should specify how employees and visitors will authenticate, because the credential choice affects controller requirements, physical mounting, throughput and software integration.

03

Is a 900 mm lane available?

Yes. ZKTeco specifies 660 mm as the standard lane width and 900 mm as an option. The wider lane can be relevant where the entrance needs more clearance for wheelchairs, assisted passage, bags or equipment. The full floor plan and accessibility requirements should be reviewed rather than selecting width based only on the gate specification.

04

Can it integrate with ZKTeco software?

Supported software depends on the equipped access controller. ZKTeco references ZKEasyGO, ZKBio Access and ZKBio CVSecurity in current product information. Before purchase, confirm the controller model, software platform and any existing database or credential environment so the final configuration is selected around the actual system rather than a generic compatibility assumption.

05

What should be prepared at the installation site?

ZKTeco specifies indoor use and a flat, level finished floor, with a base plate option for unfinished flooring. The project should also plan power, access-control cabling, fire-alarm input, controller location, lane spacing, reader position and service access. Final floor finish and cable routes are best confirmed before equipment arrives to avoid rework during commissioning.

06

How does the gate behave during a power failure?

The official specifications state that the barrier supports automatic opening when power is lost and provides a voltage-free input for a fire-alarm fail state. The project installer should still test the exact emergency behaviour after commissioning. Emergency egress is a system-level requirement involving the gate, power, alarm interface and building safety plan.

07

Is the Comet-S1000 available in Dubai?

FourTeck can review current supply options for Dubai and other UAE projects. Availability may depend on lane configuration, credential reader, controller, barrier material, project quantity and supplier status. Send the required configuration and delivery location when requesting a quote so availability can be checked against the actual build rather than the base model name alone.

08

What information should I provide for a quotation?

Provide the number of lanes, preferred lane width, credential method, expected user type, existing controller or software, project location, installation requirement, target delivery date and any accessibility or visitor-management needs. Photos or floor plans are useful for replacement projects. With those details, FourTeck can prepare a more relevant quotation and identify whether accessories or an alternative gate family should be considered.

09

Can businesses request multiple lanes for a project?

Yes, project quantities can be discussed, but the lane arrangement should be defined first. Multi-lane layouts may use the Comet-S1000 with the companion S1200 configuration depending on the design. Share a floor plan or lane sketch showing directions, wide-lane requirements and reception position so the hardware quantity reflects the intended entrance rather than a simple count of cabinets.

10

Should I choose Comet or another ZKTeco swing barrier?

Choose based on environment, lane layout, cabinet design, credential workflow and project constraints. The Comet platform is specifically listed for indoor use and emphasizes a slim cast-aluminium design with multiple credential options. If the site needs sheltered outdoor use, different materials or another security level, a Saturn, Mars or other ZKTeco entrance-control family may be worth reviewing with FourTeck.

Buying assistance

Need help specifying the right entrance-control configuration?

FourTeck can review the intended use, lane quantity, credential choice, passage width, controller, software environment, delivery location and installation expectations before preparing a quote. This is particularly useful when the entrance must support both employee access and visitor handling or when a wider accessible lane is part of the project.

Share the model, lane count, authentication method, delivery location, target date and any floor-plan details available.

Contact FourTeck Sales

Need help buying?Get Quote

Scroll to Top