ZKTeco Comet-S1200 Dual-Wing Swing Barrier

ZKTeco Comet-S1200 Dual-Wing Swing Barrier

The ZKTeco Comet-S1200 is a dual-wing swing barrier module for professional indoor entrance-control projects where businesses need orderly pedestrian flow, flexible credential choices and a cleaner architectural appearance than a traditional turnstile. Designed as part of the Comet Series, it can be combined with the Comet-S1000 to create controlled lanes for corporate offices, commercial buildings, education facilities, hospitality environments and other managed entrances. Buyers can plan standard 660 mm lanes or an optional 900 mm width, while authentication can be configured around RFID, QR code, fingerprint or facial-recognition options depending on the selected controller and reader arrangement. Safety functions include infrared sensing, anti-panic and anti-collision clutch behaviour, fire-signal integration and automatic opening during power loss. FourTeck supports UAE buyers with model selection, lane-layout review, credential and controller matching, installation requirement guidance, quotation assistance and delivery coordination. Availability, final configuration, warranty terms and project lead time can vary by selected options and supplier status. Contact FourTeck with the required lane count, passage width, credential method, site location and quantity to receive a suitable Dubai or UAE quotation.

SKU: ZKTECO-COMET-S1200-UAE Category:
Smart entrance control · swing barrier

ZKTeco Comet-S1200 Dual-Wing Swing Barrier in Dubai, UAE

A dual-wing indoor speed-gate module for controlled pedestrian lanes, designed to work with the Comet-S1000 and support multiple credential technologies.

The Comet-S1200 is most relevant to facilities teams, security integrators, consultants and procurement departments that need a polished entrance lane with configurable passage width, rapid swing movement, presence sensing and emergency-opening behaviour. Final reader, controller, software and lane arrangement should be confirmed before ordering because these choices affect the complete system design.

660 mm standard lane900 mm optional laneMulti-credential options

Request QuoteReview Specifications

Quick product information
BrandZKTeco
ModelComet-S1200
Product typeDual-wing swing barrier module
Lane width660 mm standard; 900 mm optional
Movement0.8 s open / close movement
MotorDC brushless
AvailabilityContact FourTeck for current options
WarrantyConfirm terms with quotation
Product overview

A speed-gate module built around controlled flow, flexible credentials and modern interiors

The Comet-S1200 is not a complete stand-alone lane in the same sense as a single outer cabinet. ZKTeco defines it as the dual-wing member of the Comet Series and specifies it for use with the Comet-S1000. In practical project terms, this makes the S1200 especially useful as a centre module when a site needs adjacent controlled lanes. Understanding that role at the start prevents a common procurement mistake: ordering only by model number without first deciding the number of lanes and the outer-versus-centre cabinet arrangement.

The system uses swing barriers driven by a DC brushless motor, with a stated movement time of 0.8 seconds for opening or closing. Standard lane width is 660 mm, with a 900 mm option for projects that require a wider passage. The chassis is based on 3 mm cast aluminium alloy, the standard lid is black tempered glass, and the standard door leaf is clear acrylic, with clear tempered glass also listed as an option. These material and layout choices allow the gate to fit reception areas and front-of-house zones where the appearance of the entrance is almost as important as the access-control function.

Authentication can be planned around RFID, QR code, fingerprint or facial recognition. ZKTeco lists both under-mount and top-mount options, with supported readers or terminals depending on the chosen arrangement. Because credential hardware and controller choice influence software compatibility, reader cut-outs, user experience and final price, buyers should define the intended access method before asking for a final quotation. A corporate office using employee cards has a different requirement from a visitor-heavy building that wants QR passes, while a high-security area may need biometric verification.

For UAE projects, FourTeck can help translate those requirements into a more useful product request. Instead of quoting a cabinet in isolation, the discussion can cover lane count, passage width, controller, credential method, software environment, emergency input, floor readiness, installation scope and required delivery location. That produces a specification that is easier for facilities, IT and security teams to review together and reduces the chance of missing the accessories or companion modules required for a working entrance-control lane.

Key business benefits

Why the Comet platform can work well in managed business entrances

Its value comes from combining lane control, configurable credentials and safety logic in a slim architectural format rather than relying on a single authentication method or a basic mechanical barrier.

01 · Flow planning

Build adjacent lanes without turning the entrance into a bulky barrier wall

The S1200’s dual-wing role is especially relevant to multi-lane arrangements. Used with Comet-S1000 outer modules, it can help facilities teams create parallel controlled passages while keeping cabinet width narrow. This is useful in reception zones where circulation, furniture and architectural sightlines all compete for floor space.

02 · Credentials

Match the gate to the identity method already used by the business

RFID, QR, fingerprint and facial-recognition options give buyers room to align the entrance with employee badges, visitor passes or biometric workflows. The correct reader and controller still need confirmation, but the platform reduces pressure to redesign the physical lane when credential strategy changes.

03 · Safety

Presence sensing supports safer movement through the lane

Eight pairs of infrared sensors are listed as standard, supported by safety-force sensing and lower safety sensors. The logic can detect passage conditions and work with anti-pinch functions, which matters when the gate is placed where employees, visitors, children or assisted users may pass through.

04 · Emergency behaviour

Plan controlled entry without ignoring emergency egress conditions

The series supports a voltage-free fire signal input, automatic opening when power is lost and mechanical anti-panic behaviour. These capabilities help the gate participate in a broader building-safety plan, although the final installation must still be reviewed against site-specific life-safety requirements.

05 · Feedback

Give users clear visual and audible lane status

A customizable seven-colour RGB strip runs along the lid, with defined colours for standby, normal use, closing and alarm states. An internal buzzer adds audible feedback. Clear feedback can reduce hesitation at busy reception areas and help people understand when to proceed.

06 · Lifecycle planning

Use published reliability metrics as one input to maintenance planning

ZKTeco lists a mean cycles between failure figure of six million and a mean time to repair of less than 60 minutes. These are manufacturer parameters rather than a guarantee of site uptime, but they give facilities teams useful reference points when comparing the gate’s intended duty with expected daily traffic and maintenance procedures.

Product highlights

The technical strengths that matter most at the entrance

A gate can have impressive electronics and still be a poor fit if lane layout, reader placement or emergency behaviour are wrong. The Comet Series is strongest when those factors are treated as one design problem. The S1200’s dual-wing construction, narrow 115 mm cabinet depth across a 1500 mm length, sensor coverage and configurable authentication options give consultants several ways to shape the user journey without changing the fundamental barrier technology.

Throughput also depends on authentication method rather than barrier speed alone. ZKTeco publishes up to 30 passengers per minute for RFID and QR, 20 for fingerprint and 15 for face. That difference is important for offices with large shift changes or morning peaks. A buyer should therefore estimate not only average daily users, but also the largest number likely to arrive in a short period and the credential method those users will present.

Technical specifications

ZKTeco Comet-S1200 specification reference

These values reflect published Comet Series parameters. Reader, controller, display, software, door-leaf material, lane width and colour can vary with the selected configuration. Confirm the exact bill of materials before purchase.

Specification Published detail Buyer note
Brand / model ZKTeco Comet-S1200 Dual-wing Comet Series module
Lane type Dual wings, used with Comet-S1000 Confirm complete lane combination
Lane width 660 mm standard; 900 mm optional Choose for traffic and accessibility plan
Barrier movement Swing; 0.8 s per opening or closing movement Throughput still depends on credential method
Motor DC brushless motor Designed for repeated gate movement
Chassis 3 mm cast aluminium alloy Silver standard; gold optional
Door leaf Clear acrylic 630 × 295 mm standard; clear tempered glass option Material selection may affect project specification
Sensors 8 pairs of IR sensors standard, high position Supports presence and passage logic
Credential options RFID, QR code, fingerprint, facial recognition Reader / terminal choice is configuration dependent
Published flow rate RFID 30 ppm; QR 30 ppm; fingerprint 20 ppm; face 15 ppm Site workflow can change real throughput
Power supply 110 / 220 V AC at 50–60 Hz Coordinate local electrical provision
Power rating 20 VA standby; 120 VA operation Include in power and backup planning
Fire / communication Voltage-free fire input; one fire-alarm relay port; one RS485 port Integration should be checked against site design
Dimensions 1500 × 115 × 1000 mm standard Verify floor plan and fixing space
Net / gross weight 65 kg / 80 kg for Comet-S1200 Relevant to handling and installation planning
Operating conditions -28°C to 60°C; 95% RH non-condensing Manufacturer classifies application as indoor
Noise Less than 60 dB Useful for lobby and office environments
Reliability references MCBF 6 million; MTTR less than 60 minutes Manufacturer parameters, not a site uptime guarantee
Software ZKEasyGO, ZKBio Access or ZKBio CVSecurity depending on controller Confirm controller and software version
Delivery / site prep Pre-assembled; flat and level finished floor recommended Base plate option noted for unfinished floor

The most important choices are lane width, number of lanes and authentication method. A 660 mm passage may suit standard staff traffic, while a 900 mm option can be considered when the project calls for a wider walkway. Credential technology changes the expected flow rate and may also change the top-lid hardware, display and controller requirements. For this reason, compare complete configured lanes rather than comparing only the central module price. Buyers should also confirm the chosen software environment, reader models, power supply arrangement and emergency input before final approval. If the site is still under construction, share the floor finish and planned cable routes so installation requirements can be reviewed before the entrance furniture is fixed in place.

Configuration and buyer guidance

Define the lane first, then choose the electronics

The correct purchase is a complete entrance design, not simply a Comet-S1200 cabinet. Before requesting a quotation, establish how people will move through the space, what credentials they will present and how the gate should behave during normal, denied and emergency conditions.

01 / CONFIRM

How many lanes are required?

This is the highest-risk question because the S1200 is a dual-wing module designed to work with the S1000. Draw the lane arrangement and confirm which cabinets form the outside edges and which modules sit between adjacent passages.

02 / MATCH

Which credential should users present?

Cards and QR codes can support faster published throughput than fingerprint or face. Choose based on existing staff credentials, visitor workflow, security policy and whether readers need to be under-mounted or placed on top-mounted poles.

03 / PLAN

Is 660 mm enough, or is 900 mm needed?

The wider option can affect floor planning and the overall entrance footprint. Consider luggage, trolleys, mobility needs and building-access requirements rather than selecting a width only from the datasheet.

04 / CHECK

What controller and software will manage access?

Software support depends on the equipped controller. Confirm whether the project will use ZKEasyGO, ZKBio Access, ZKBio CVSecurity or another compatible access-control architecture before final hardware selection.

05 / REVIEW

Is the site physically ready?

The manufacturer calls for a flat, level finished floor and lists a base plate option for unfinished flooring. Cable routes, power, fire signal and controller connectivity should be planned before decorative finishes make changes expensive.

06 / VERIFY

What support and warranty expectations apply?

Warranty period, installation scope, commissioning and support response can vary by supply arrangement. Ask for these commercial details to be written into the quotation rather than assuming they are identical for every project.

For a useful FourTeck quote, send the lane count, preferred width, authentication method, existing access-control platform, approximate daily and peak traffic, delivery location, required project date and whether installation or commissioning assistance is needed. A simple lobby drawing or marked floor plan can make the first review significantly more accurate.

Ideal business use cases

Where a dual-wing speed gate makes practical sense

The strongest use cases are indoor sites where controlled pedestrian flow, architectural presentation and multiple credential choices all matter at the same time.

PRIMARY USE

Corporate reception and multi-lane office lobbies

Large office buildings often need several parallel lanes so employees can enter quickly while visitors are directed through a managed process. The Comet-S1200’s centre-module role fits this architecture well, especially when paired with outer Comet-S1000 units. RFID can support staff badge entry, while QR or biometric options can be considered for visitor or higher-assurance workflows. The slim profile and transparent barrier materials help the entrance remain visually open rather than feeling like a heavy industrial checkpoint.

Commercial towers

Shared office towers need to process different tenant populations while keeping entry records and lane behaviour consistent. A configurable credential platform allows building management to align the gate with the chosen access-control system and visitor process.

Education facilities

Universities, training centres and selected campus buildings may use controlled gates to separate public reception from staff or student-only areas. Sensor coverage and accompanied child-management considerations are relevant when varied user heights and movement patterns are expected.

Hospitality and premium venues

Hotels, clubs and managed venues may prefer an entrance control device that supports QR or card credentials without looking like industrial infrastructure. The glass-and-aluminium design language can suit front-of-house spaces when the lane is integrated carefully with reception furniture and signage.

Headquarters and secure departments

Where a company wants an extra controlled boundary after the main lobby, biometric or card authentication can be matched to internal access policies. The gate’s anti-tailgating and wrong-way alarm logic can support that controlled transition.

Visitor-management projects

QR credential capability can be useful where guests receive temporary digital passes. The complete workflow still depends on the selected access controller and visitor software, so integration should be confirmed before the lane hardware is finalized.

Feature deep dive 01

Comet-S1200 Multi-Credential Access Design

The gate can support several authentication technologies, but the best option is the one that matches the operating process. RFID is a strong fit for employees who already carry building cards because the interaction is familiar and ZKTeco lists the highest published flow rate of 30 passengers per minute for that method. QR code offers the same published rate and can be attractive for visitor or event workflows where temporary credentials are issued digitally. Fingerprint and face provide biometric choices, with published flow rates of 20 and 15 passengers per minute respectively.

The physical mounting method matters as well. ZKTeco lists streamlined under-mount options for RFID, QR, fingerprint and facial-recognition configurations, plus top-mount poles compatible with selected face terminals. Under-mount facial configurations can also include one or two 7-inch IPS touch displays. These choices affect what users see as they approach the lane and how much space is required above the cabinet.

For buyers, the practical decision is not “which technology is most advanced?” but “which credential gives the right balance of speed, identity assurance, user convenience and integration effort?” A building that already has a mature card system may gain little by switching every employee to biometrics. A new flagship headquarters, by contrast, may value facial recognition at selected lanes. FourTeck can review the intended workflow and help align the lane hardware with the chosen access-control architecture before the final order is prepared.

Feature deep dive 02

Comet-S1200 Safety, Detection and Emergency Behaviour

Entrance control must prevent unwanted passage without creating an unreasonable hazard for legitimate users. ZKTeco addresses this with eight pairs of infrared sensors, safety-force sensing, lower safety sensors, accurate presence sensing and emitter/receiver infrared technology. The controller also supports anti-pinch configuration. Together, these functions help the system understand whether someone is in the passage and respond according to the configured access mode.

The mechanical clutch adds anti-panic and anti-collision behaviour, while the system can automatically open on power loss. A voltage-free contact input is provided for fire-alarm fail-state integration, and ZKTeco lists emergency mode with automatic door unlocking. These are significant capabilities for a controlled lobby because access restrictions should not be designed independently of emergency movement. The exact connection to the building fire system, exit strategy and local safety requirements still needs project-level review by the appropriate responsible parties.

8 IR sensor pairsStandard high-position sensing supports passage detection.
Fire signal inputVoltage-free contact allows coordinated fail-state behaviour.
Power-loss openingThe barrier is designed to open automatically if power is lost.

A buyer should ask the integrator to demonstrate normal entry, denied entry, tailgating detection, wrong-way movement, obstruction handling, fire input and power-loss behaviour during commissioning. That functional test is more valuable than simply confirming that the barrier opens when a card is presented.

Feature deep dive 03

Comet-S1200 Lane Architecture and Site Readiness

The physical lane plan is where many otherwise sound access-control projects become difficult. The Comet cabinet is 1500 mm long, 115 mm wide and 1000 mm high in its standard configuration, and the S1200 weighs about 65 kg net. Those numbers need to be translated into actual floor positions, clear walkway widths, maintenance access and cable entry points. The manufacturer recommends a flat and level finished floor and lists a base plate option for unfinished floors.

The S1200 also has a special role in a multi-lane arrangement because it provides dual wings. That means the overall entrance cannot be designed by multiplying cabinet width by lane count. A drawing should show each S1000 and S1200 position, each 660 mm or 900 mm passage, approach space, reader orientation and nearby walls or reception furniture. This is particularly important when accessible routes, visitor desks or queuing rails share the same lobby.

Site-readiness checklist

  • Confirm the finished-floor level and fixing method.
  • Mark the exact centre line of every cabinet and passage.
  • Decide whether each lane is 660 mm or 900 mm wide.
  • Plan electrical supply, access-control wiring, RS485 and fire-alarm input.
  • Confirm the direction of travel and reader location for entry and exit.
  • Allow service access and protect cables before floor finishes are closed.
  • Check the project’s accessibility and life-safety requirements.

For new construction, this review should happen before final floor finishes. For an existing lobby, take measurements and photos from both approach directions. FourTeck can use that information to help identify whether the proposed module count and lane width are consistent with the intended layout before a commercial quotation is finalized.

Buyer decision guide

What Buyers Should Check Before Purchase

The biggest purchase risk is treating the Comet-S1200 as an isolated product rather than one component of a complete entrance lane. Confirm lane architecture, credentials, integration and commercial scope together so the delivered hardware can be commissioned without unexpected redesign.

01 / FIT

Configuration Fit

Confirm the complete S1000/S1200 combination, lane count and passage width. Then select acrylic or tempered-glass leaves, standard silver or optional gold chassis, and the intended reader arrangement. A quote should identify these choices clearly rather than describing only “Comet-S1200”.

02 / MATCH

Compatibility Check

Check the selected access controller, credential reader and management software as a group. ZKTeco’s supported software depends on the equipped controller. If the site already has card databases, visitor software or a building access platform, confirm how the gate will exchange permission and event data.

03 / TERMS

Availability and Warranty

Ask for current availability, lead time, warranty terms, delivery scope, installation responsibility and commissioning support in writing. These commercial conditions can vary by configuration, order quantity and supplier status. Do not assume that a reader, controller, base plate or software license is included unless the quotation lists it.

04 / REQUEST

Quote Preparation

Provide quantity, number of lanes, required width, authentication method, expected peak traffic, existing software, floor condition, delivery location and target date. If the requirement is part of a larger project, also state whether cabling, access controller, fire integration and installation should be included.

Buyers often ask whether the 900 mm version is automatically the better choice. It is not. Wider passage can be useful for accessibility, bags or trolleys, but it also changes the entrance footprint. Likewise, facial recognition is not automatically better than RFID; it provides a different identity workflow and has a lower published passenger rate. The right configuration is the one that fits the people, security policy and physical entrance. FourTeck can help review these trade-offs before the request is converted into a final bill of materials.

UAE availability and service support

Project-oriented supply support for UAE entrance-control requirements

FourTeck supports inquiries for the ZKTeco Comet-S1200 in Dubai and across the UAE with a focus on getting the requested configuration clear before commercial approval. Availability can vary according to lane width, door-leaf material, credential reader, controller, colour option, quantity and supplier status, so the most useful first step is to identify the complete lane requirement rather than asking only whether the central module is available.

Selection supportReview lane count, width, credential method and controller choices before quotation.
Delivery coordinationPlan project delivery around confirmed configuration, order quantity and site schedule.
Warranty guidanceConfirm applicable warranty terms and support scope as part of the quotation.

If installation is required, include the floor condition, power point, fire-alarm interface, cable routes and existing access-control infrastructure in the inquiry. This allows the supply conversation to include practical deployment concerns rather than leaving them until after equipment arrives. For multi-lane projects, a drawing is particularly valuable because the number of S1000 and S1200 modules depends on the planned arrangement.

Check UAE Availability

UAE project coverage

Support for Dubai, Abu Dhabi, Sharjah and Ajman projects

Businesses and integrators in Dubai, Abu Dhabi, Sharjah and Ajman can contact FourTeck for product-selection assistance, configuration review and quotation support for entrance-control requirements. The same product may be specified differently from one site to another: a corporate tower may need multiple RFID lanes, a visitor centre may prioritize QR access, and a premium reception may require particular finish and barrier-material choices.

For each location, share the number of entry and exit passages, expected traffic, preferred credential method and any installation constraints. FourTeck can then help identify what should be included in the supply request and coordinate the quotation around the project rather than treating every location as an identical order. Delivery timing and final availability remain dependent on selected configuration, quantity and supplier status.

Regional inquiry support

GCC and Africa procurement coordination

FourTeck also receives business technology inquiries from selected GCC and Africa markets. Organizations in Saudi Arabia, Qatar, Oman, Kuwait and Bahrain, as well as projects in Kenya, Uganda and other Africa-region markets, may have different delivery, warranty, customs, installation and supplier conditions. For that reason, regional requests should be evaluated by destination rather than assuming the same commercial terms that apply to a UAE order.

A multi-country rollout should define a common technical standard first: lane width, credential type, controller, management software, colour and barrier material. Local differences can then be documented separately for electrical provision, civil work, delivery and site support. This approach makes it easier to keep the user experience consistent across branches while allowing project-specific installation details to vary where necessary.

Regional inquiries can use the relevant FourTeck platforms for local communication. Explore FourTeck Kuwait, FourTeck Kenya, FourTeck Uganda or FourTeck Africa for region-specific inquiry routing. Product availability, warranty handling and delivery scope should be confirmed for the destination market before purchase.

Related FourTeck solutions

Other options buyers may consider around the entrance-control project

A complete entrance project often needs companion modules, access-control services and alternative gate types. The alternatives below are intended as decision prompts; final suitability depends on site layout and the required security workflow.

RECOMMENDED COMPANION

ZKTeco Comet-S1000 single-lane module

The S1000 is the key companion to the S1200 because ZKTeco specifies the dual-wing module for use with it. Multi-lane projects should calculate the correct combination of outer and centre cabinets before ordering.

Explore access-control solutions →

ZKTeco Saturn Series swing barriers

Consider Saturn Series models when the project calls for a different enclosure design, gate architecture or configuration path. Compare exact variant specifications before substitution.

Review physical security options →

ZKTeco SBTL Series

The SBTL family can be relevant when a buyer wants to compare alternative swing-barrier formats within the ZKTeco portfolio. Lane width, throughput and reader integration should be compared model by model.

Discuss IT and security project support →

Access-control readers and controllers

The gate needs a credential and control architecture. Reader type, controller and software should be selected together so physical access and event management work as intended.

See access-control system services →

Entrance-control installation support

Projects that require floor fixing, wiring, fire-signal coordination and commissioning should define installation scope separately from the hardware list.

Request project assistance →

Why buyers choose FourTeck

Buying support that looks beyond the model number

Entrance-control equipment sits at the intersection of physical security, facilities, electrical work, access-control software and daily user experience. FourTeck’s role is to help buyers frame those dependencies before they become purchasing problems. That means discussing what the gate has to accomplish, how many people will use it, what credential they already carry, how the lane fits the lobby and which systems need to exchange signals.

01 · Product sourcing supportCurrent options can be reviewed against model, quantity and configuration rather than assuming every variant is immediately available.
02 · Configuration guidanceLane width, module combination, readers, controller and software can be considered as one procurement package.
03 · Pre-sales consultationA drawing, site photo or written workflow can be reviewed to identify questions that should be answered before order placement.
04 · UAE delivery coordinationDelivery planning can be aligned with the confirmed supplier position, quantity and project schedule.
05 · Warranty guidanceCommercial terms can be clarified in the quotation so buyers understand what warranty and support arrangement applies.
06 · Related-system matchingThe gate can be discussed alongside access control, CCTV, networking, power and structured cabling where those systems form part of the same project.

This approach is useful for both SMB and enterprise buyers. A small office may need one controlled lane and a simple card workflow, while a large commercial building may need several lanes, visitor QR passes, biometric options, centralized management and formal testing. In either case, a clear requirement helps procurement compare quotations on equivalent scope. Buyers can also review FourTeck’s CCTV and access-control services or the wider business IT services portfolio when the gate is part of a broader technology project.

Frequently asked questions

Common questions about the Comet-S1200

01

What is the ZKTeco Comet-S1200 used for?

It is a dual-wing swing-barrier module used in controlled indoor pedestrian entrances. ZKTeco specifies the S1200 for use with the Comet-S1000, making it particularly relevant to multi-lane speed-gate layouts in corporate lobbies, commercial buildings and other managed facilities. The gate can work with RFID, QR code, fingerprint or facial-recognition options depending on the selected configuration.

02

Can the Comet-S1200 be used by itself?

The published lane description says the Comet-S1200 is a dual-wing model used with the Comet-S1000. Buyers should therefore plan the complete lane combination rather than treating the S1200 as a stand-alone outer cabinet. For a one-lane or multi-lane project, provide the intended layout to FourTeck so the required module count can be reviewed before quotation.

03

Which passage width should I choose?

ZKTeco lists 660 mm as standard and 900 mm as an option. The right choice depends on floor space, user profile, luggage or trolley movement, accessibility requirements and the overall entrance plan. A wider lane is not automatically better because it changes the total footprint. Review the actual lobby dimensions and movement requirements before selecting width.

04

How fast can people pass through the gate?

The barrier movement is listed at 0.8 seconds, but credential method determines the published passenger rate. ZKTeco states up to 30 passengers per minute for RFID and QR, 20 for fingerprint and 15 for facial recognition. Real site throughput can be lower because user behaviour, credential presentation, queuing and controller response also influence the flow.

05

Does it support fire-alarm integration and power-loss opening?

Yes. The published parameters include a voltage-free fire-signal input and automatic opening on power loss, together with emergency unlocking behaviour. These functions should still be connected and tested as part of the building’s approved safety design. The gate specification does not replace site-specific life-safety review or commissioning by the responsible project parties.

06

Which access-control software can be used?

ZKTeco lists ZKEasyGO, ZKBio Access and ZKBio CVSecurity as supported software options depending on the equipped access controller. Because the controller is a configuration decision, buyers should confirm the exact hardware and software combination before ordering. If an existing platform is already installed, share its version and controller details for compatibility review.

07

Is the gate suitable for outdoor installation?

ZKTeco classifies the Comet Series application environment as indoor. Buyers should therefore not assume that the published operating-temperature range means the gate is approved for exposed outdoor use. If the project involves an entrance near exterior conditions, provide the exact location and shelter arrangement so an appropriate product or installation approach can be considered.

08

Can FourTeck help specify readers and lane modules?

FourTeck can help review the requested lane count, passage width, credential method, reader arrangement, controller, software environment and project location before preparing a commercial response. This is particularly useful for multi-lane layouts because the S1000 and S1200 modules must be combined correctly. Final technical scope should be confirmed in the quotation.

09

What should I provide when asking for a UAE quote?

Send the required quantity, number of lanes, standard or 900 mm width, credential type, expected users, current access-control platform, delivery location, target project date and whether installation or commissioning is required. A lobby drawing or floor plan is highly useful. Availability, lead time, warranty and final commercial terms can then be confirmed against the selected configuration.

10

Can businesses request multiple lanes or project quantities?

Yes, businesses can request project quantities or multi-lane configurations. The key is to specify the total number of passages and the desired lane arrangement so the correct mix of S1000 and S1200 modules can be reviewed. For larger projects, also include phased delivery needs, credential standards, software expectations and site locations to make the quotation easier to compare and implement.

Buying assistance

Need Help Building the Correct Comet Lane Configuration?

FourTeck can review the intended lane count, passage width, credential method, controller, software, site readiness, quantity and delivery location before preparing a quote. This helps ensure the request covers the complete entrance-control requirement rather than only one cabinet.

Share your model requirement, number of lanes, preferred width, credential technology, project location and target date.

Contact FourTeck Sales

Need help buying?Get Quote