ZKTeco LockerPad-7B Smart Locker Terminal in Dubai, UAE
A networked biometric terminal for managing electronic locker access with face recognition, card-reader integration, touchscreen operation, and centralized ZKBio CVSecurity management.
It is suited to organizations that want self-service lockers without relying on physical keys for every user. The key procurement questions are the number of cabinets, required lock-control boards, authentication method, software environment, power arrangement, and the exact accessories included in the proposed bill of materials.
Face + Card Options
ZKBio CVSecurity
A control point for self-service electronic lockers
The LockerPad-7B is designed to sit at the center of an electronic locker system rather than function as a complete locker cabinet by itself. It provides the user interface, biometric identification, network communication, and management connection needed to let approved users open assigned or available cabinets. ZKTeco specifies support for up to eight lock-control boards over RS485, with each board providing twelve relay outputs, giving a published cabinet capacity of up to 96. This architecture is useful when a project needs a single terminal to coordinate many locker doors while keeping administration centralized.
For the user, the system can provide keyless access through visible-light face recognition, while supported external card readers can add 125 kHz ID, 13.56 MHz IC, or multi-technology card options depending on the selected reader module. For the administrator, ZKBio CVSecurity provides the management layer for assigning rights, monitoring locker states, handling fixed or temporary users, and viewing operational information. That means the terminal is not simply a door-release device: it belongs in a wider workflow covering enrollment, locker allocation, event records, user permissions, and exception handling.
This makes the platform relevant to gyms, staff facilities, education environments, museums, libraries, swimming pools, retail sites, parcel collection areas, clubs, and other locations where people need temporary or recurring access to secure compartments. The exact cabinet construction, lock type, control-board quantity, card-reader choice, power supply arrangement, network topology, and software deployment still need to be planned around the project. A buyer should therefore avoid ordering by terminal model alone.
For UAE projects, FourTeck can help translate the locker count and user workflow into a clearer purchase request. Share how many doors must be controlled, whether users are permanent or temporary, whether face-only or card-assisted access is preferred, where ZKBio CVSecurity will run, and whether the project includes cabinet fabrication or only the electronic control layer. This gives the quotation process enough context to identify the terminal, lock-control boards, readers, power components, network requirements, and support expectations more accurately.
Key business benefits
The strongest value comes from combining user verification, locker control, and centralized administration in one deployment model. The benefit is operational control rather than simply replacing a mechanical key.
One terminal can coordinate a larger locker bank
With up to eight RS485 lock-control boards and twelve relay outputs per board, the published design can address as many as 96 cabinets. This helps projects avoid placing a full biometric terminal on every door. The result can be a cleaner user experience, a more centralized control point, and a simpler path for administrators who need to monitor locker use from a shared system.
Reduce dependence on physical keys
Face recognition lets an enrolled user authenticate without carrying a locker key. In environments with rotating users, this can reduce key handling, handover, and replacement tasks. Card verification can also be added through supported external readers when an organization wants credentials that match an existing access policy.
Give administrators better locker status awareness
ZKBio CVSecurity can present information about cabinets being open, locked, available, occupied, blocked, or available for allocation. This matters when front-desk or security staff need to understand the state of a locker bank without physically inspecting every door.
Capacity for busy shared environments
The Middle East specification lists 10,000 face users, 10,000 card users, and up to 200,000 transaction records. That gives procurement teams a useful reference when planning a locker system for a facility with many registered users or frequent daily access events, while final regional firmware and configuration should still be confirmed before ordering.
Multiple communications paths for system design
TCP/IP and Wi-Fi support help place the terminal on the management network, while RS485 is used for lock-control boards. USB, RS232, Wiegand input, and Wiegand output extend the available integration options. Buyers should map these interfaces to the selected readers, locks, network, and software before installation.
Touchscreen self-service for everyday use
The 7-inch 720 × 1280 display gives the locker station a clear local interface. ZKTeco also documents image and video content support for digital advertising, which may be useful in customer-facing sites. In practical buying terms, the screen supports both operational interaction and selected information-display use cases without requiring a separate kiosk screen.
The details that most affect a locker project
A smart locker terminal should be evaluated as part of a complete cabinet-control workflow. Locker count, reader method, software, power, lock-control boards, and installation design are more important than the screen size alone.
The terminal uses a quad-core 1.8 GHz processor with 2 GB RAM and 16 GB ROM and runs Android 5.1.1 according to the vendor specification. Its physical size is 113 × 210 × 22 mm. The published operating range is -10°C to 45°C with 10% to 90% humidity. These values help an installer check mounting and environmental fit, but they do not replace cabinet-level engineering. The terminal is only one component: cabinets, electric locks, wiring, lock-control boards, suitable power supplies, external readers where required, network connectivity, and the ZKBio CVSecurity environment must be planned together. For a commercial proposal, ask for a component-level scope instead of assuming that every necessary locker part is included with the terminal.
Technical specifications
The table below follows ZKTeco Middle East’s published data for the LockerPad-7B. Confirm the exact regional version, firmware, accessories, and lock-control components on the quotation.
| Specification | Published detail | Buyer note |
|---|---|---|
| Brand / model | ZKTeco LockerPad-7B | Smart locker control terminal |
| Cabinet capacity | Up to 96 cabinets | Requires up to 8 lock-control boards; cabinets not included |
| Face capacity | 10,000 (1:N) | Confirm current regional firmware |
| Card capacity | 10,000 | External reader / module choice matters |
| Transaction capacity | 200,000 | Middle East specification; verify selected version |
| Processor | Quad-core 1.8 GHz | Terminal platform specification |
| Memory | 2 GB RAM / 16 GB ROM | Fixed platform resource |
| Operating system | Android 5.1.1 | Check software lifecycle expectations |
| Biometric algorithm | ZKFace 5.6.2 | Visible-light face recognition |
| Camera | 2MP dual lens | Published recognition distance 20–50 cm |
| Display | 7-inch LCD touch screen, 720 × 1280 | User-facing locker interface |
| Communication | TCP/IP, USB Host, RS232, RS485, Wiegand In/Out, Wi-Fi 2.4 GHz | Plan reader, board and management connections |
| Card types | 125 kHz ID standard; 13.56 MHz IC / multi-tech optional | Reader selection affects credential compatibility |
| Software | ZKBio CVSecurity | Confirm licensing and deployment scope |
| Terminal power | DC 12V 3A | Board and locks require separate power planning |
| Operating environment | -10°C to 45°C; 10% to 90% humidity | Check cabinet ventilation and site conditions |
| Dimensions | 113 × 210 × 22 mm | Allow for mounting and cable clearance |
| Published certifications | ISO14001, ISO20000, CE, FCC | Confirm documentation required for your project |
Choosing the correct configuration starts with cabinet quantity. A 24-door locker bank has different board and power requirements from a 96-door installation, even though both may use the same terminal. Next, identify the authentication workflow. Face recognition may be sufficient for enrolled users, while cards may be needed where employees already carry credentials or where a secondary method is preferred. Then confirm the management architecture: ZKBio CVSecurity needs to fit the customer’s server, network, user-administration, and licensing plan. Finally, review electrical design. The terminal has its own DC input, and the lock-control boards and electric locks also need suitable power and wiring. For a dependable quote, provide cabinet count, lock type if already selected, board quantity if known, credential technology, user count, network availability, installation site, and whether software licensing or configuration services should be included.
Configuration and buyer guidance
The most important decision is not the terminal itself; it is whether the complete locker architecture matches the number of doors, user workflow, authentication policy, software environment, and physical installation.
How many cabinet doors must one terminal control?
Count the final number of electric locks, not simply the number of locker frames. The published architecture supports up to 96 cabinets through eight twelve-output boards. A smaller deployment may need fewer boards, which affects wiring, power, enclosure space, and cost.
Which credential should users present?
Decide whether face recognition is the primary method or whether card access is required. If cards are needed, confirm whether the project uses 125 kHz ID, 13.56 MHz IC, or a multi-technology reader. Existing employee credentials should be checked before selecting the external reader.
Where will management software run?
The locker system is designed around ZKBio CVSecurity. Buyers should confirm server or hosting requirements, licensing, administrator access, network reachability, backup expectations, and whether the locker project must coexist with other ZKBio CVSecurity modules already in use.
Is the power and cabling design complete?
The terminal’s DC 12V input is only part of the power plan. Electric locks and control boards also consume power, and long cable runs introduce practical design issues. Confirm supply sizing, cable routes, protection, maintenance access, and whether backup power is required for the locker service.
What happens when normal access fails?
A business locker system needs an exception process. ZKTeco documents emergency opening from the management environment, but the project should also define who is authorized to use that function, how incidents are recorded, and what happens during network, power, or hardware faults.
What must be included in the quotation?
Ask for a component-level bill of materials: terminal, control boards, reader modules, power supplies, locks if required, cabling, cabinet-side accessories, software or license items, installation work, configuration, testing, training, delivery, and warranty terms. This avoids comparing incomplete offers.
Ideal business use cases
This terminal makes the most sense where many people share a controlled locker bank and administrators need repeatable enrollment, access assignment, and status visibility. It is less about general door access and more about managing multiple compartments through one user-facing station.
Gyms, clubs, swimming pools and staff changing areas
These environments often have recurring members plus short-term visitors, making physical key management inconvenient. Face recognition can give enrolled users a keyless method, while temporary locker assignment and centralized administration can support changing daily usage. Buyers should decide how long users keep a cabinet, how expired rights are removed, and what process applies when a user cannot authenticate.
Libraries, museums and public facilities
Visitor storage areas can benefit from a self-service workflow that does not require staff to hand out keys one by one. The terminal can provide a central interaction point, while administrators can use the management platform to monitor cabinet status. Project design should still consider visitor enrollment, privacy policy, temporary access rules, and emergency opening procedures.
Retail pickup and parcel collection
A networked locker terminal can support controlled pickup workflows where goods or parcels are stored in numbered compartments. The published feature set provides the identity and locker-control layer, but the full application process may require integration logic, user provisioning, notifications, or site-specific software configuration. Confirm the intended pickup workflow before assuming every business process is standard.
Corporate offices and shared employee storage
Companies using flexible seating or shared facilities may need secure lockers for employees who do not have permanent desks. A centrally managed locker bank can support repeat users, reduce manual key administration, and give facilities teams better visibility into cabinet usage. Existing employee card technology should be checked if the organization wants to use current badges.
Education campuses and training centers
Students, trainees, or staff can be enrolled into a controlled locker system for books, equipment, uniforms, or personal items. The 10,000-user published capacity may be useful in larger sites, while administrators can structure fixed or temporary rights. Before deployment, confirm whether the institution requires integration with existing identity records or card credentials.
Warehouses and controlled personal-item storage
Industrial sites may use lockers for employee belongings, tools, handheld devices, or controlled equipment. In this environment, the important questions include cabinet durability, environmental conditions, power resilience, user throughput, and whether the locker room is on a network that can reach the management platform. The terminal’s operating limits should be checked against the actual room conditions.
LockerPad-7B Cabinet Control Architecture
The decisive engineering feature is the separation between the user terminal and the lock-control boards. ZKTeco specifies that the terminal can connect to as many as eight control boards through RS485, and each board provides twelve relay outputs. This creates the published 96-cabinet maximum without requiring a separate biometric terminal for every locker.
For buyers, this means locker quantity drives the electronics bill of materials. A 12-door installation may need one board; a 48-door installation may need four; a full 96-door bank may use eight. But the final design is not only about board count. Cable length, wiring routes, lock current, power supply sizing, enclosure layout, maintenance access, and how the boards are distributed inside the cabinet structure all affect installation quality. The terminal should therefore be procured together with a clear cabinet-side design.
LockerPad-7B Face and Card Verification
Face recognition is the primary keyless capability, but the platform is designed to accommodate card verification through compatible reader options. That flexibility matters because locker users are not always the same type of person. A fitness member may prefer contactless face verification, an employee may already have a corporate card, and a visitor facility may need a different temporary-user process.
Before choosing a reader, test the actual credential technology used by the organization. Card frequency alone does not guarantee compatibility with every badge format, encoding method, or security policy. Likewise, biometric projects should include a clear enrollment process, privacy and retention policy, administrator permissions, fallback procedure, and user communication. These operational details turn a supported feature into a manageable business process.
LockerPad-7B Centralized Locker Management
ZKBio CVSecurity is the management layer that gives this terminal much of its business value. ZKTeco describes the platform as able to manage multiple lockers, assign access rights to fixed or temporary users, report cabinet states, and provide an emergency function that can open cabinets for authorized safety checks. This makes the deployment more manageable than a collection of independent locks.
Decision checklist
- Confirm the required ZKBio CVSecurity licensing.
- Identify where the management server will run.
- Define administrator roles and access rights.
- Plan backup and recovery expectations.
- Confirm network routes between terminal and server.
Operational workflow
Decide how users are created, how lockers are assigned, how temporary access expires, who can release a cabinet in an exception, and which events need to be retained. These rules should be written before go-live so the software configuration follows the facility’s actual process rather than an improvised setup.
Organizations that already use other ZKBio CVSecurity modules should also check version compatibility and how the locker component will fit the existing platform. A new deployment should identify server sizing, database expectations, administrator devices, network security requirements, and update policy. FourTeck can help buyers prepare these questions for a quotation, while final software architecture and licensing should be confirmed for the selected deployment.
What Buyers Should Check Before Purchase
The biggest purchase risk is ordering the terminal without defining the rest of the locker system. A correct proposal should connect cabinet quantity, electric locks, control boards, authentication, software, power, networking, deployment services, and commercial terms into one scope.
Configuration Fit
Confirm the exact door count, expected user population, face or card workflow, event-record requirement, and whether one terminal will serve the whole bank. If the requirement approaches 96 cabinets, validate board placement, wiring, power and service access early. If the project is small, do not assume every available board or reader module is necessary.
Compatibility Check
Check the electric lock type, lock current, cabinet mechanics, control-board wiring, card technology, LAN or Wi-Fi access, and ZKBio CVSecurity environment. Existing employee cards should be tested before reader selection. If another access-control platform is already in use, confirm whether the locker system will be managed separately or needs a defined integration path.
Availability and Warranty
Availability, delivery time, included accessories, warranty duration, and support process should be written on the supplier quotation. Do not assume the terminal includes cabinets or every required board. Ask how firmware, software licensing, installation, and replacement handling are covered so procurement can compare like-for-like commercial scope rather than model names only.
Quote Preparation
Provide the number of lockers, quantity of terminals, delivery location, intended use, number of users, chosen authentication method, existing card technology, lock model if known, cabinet vendor if already selected, network availability, software requirement, installation scope, target date, and warranty expectations. These details make the quote more useful and reduce later changes.
When comparing the LockerPad-7B with another locker controller, focus on the architecture and workflow rather than a single feature. A newer or higher-capacity model may be appropriate when a project needs a different operating platform, additional biometric functions, greater capacity, or newer lifecycle support; a simpler setup may be adequate when only a small number of cabinets and basic user verification are required. FourTeck can review the project requirement and help identify whether this model is suitable or whether another ZKTeco locker terminal should be considered.
UAE availability and service support
FourTeck supports product inquiries across Dubai and the UAE with assistance for model selection, configuration review, quotation, delivery coordination, and warranty guidance. Availability can vary according to supplier status, required quantity, regional version, control-board requirement, reader options, and project timing, so the commercial offer should be treated as configuration dependent until the scope is confirmed.
For a useful UAE quote, send the terminal model, locker count, preferred verification method, quantity, delivery address, software requirement, and whether you need only supply or a broader integration discussion. If cabinets are being built by another contractor, sharing the cabinet drawings, lock specification, board mounting area, and wiring plan can help identify interface questions early. Contact FourTeck for current LockerPad-7B availability and configuration assistance.
Dubai, Abu Dhabi, Sharjah and Ajman coverage
Businesses in Dubai, Abu Dhabi, Sharjah, Ajman and other UAE locations can contact FourTeck for smart-locker product selection, quotation assistance and project-scope review. The same terminal can be used in different types of facilities, but the bill of materials may differ substantially depending on the cabinet manufacturer, number of doors, reader method, software arrangement and site services.
For a multi-site rollout, buyers should also decide whether every site uses the same locker size, terminal quantity, control-board layout, credential type and management policy. Standardizing these choices can make deployment and support more consistent, while location-specific differences such as network access, electrical works, cabinet dimensions and user volume should still be documented. FourTeck can help turn that site information into a more structured inquiry before commercial confirmation.
GCC and Africa availability
FourTeck also supports business technology inquiries across selected GCC and Africa markets through regional inquiry channels. Customers in Saudi Arabia, Qatar, Oman, Kuwait and Bahrain, as well as organizations with requirements in Kenya, Uganda and other Africa locations, can discuss product sourcing, project quantities, configuration requirements and delivery planning. Availability, warranty handling, transport options, taxes, local compliance and support scope may vary by country and supplier channel.
For smart-locker projects, cross-border supply needs more preparation than shipping a standalone terminal. The buyer should clarify whether lockers and locks are sourced locally, whether control boards and power supplies are included from the same supplier, whether ZKBio CVSecurity will be hosted centrally or per country, and who is responsible for installation and commissioning. These decisions determine whether the project is a simple hardware supply or a coordinated multi-component rollout.
Regional buyers can begin with FourTeck UAE or use the relevant regional platforms for Kenya inquiries, Uganda inquiries, Africa regional support, or Kuwait business inquiries. Product and service scope should be confirmed for each destination before ordering.
Other options buyers may consider
A complete locker system often includes more than the terminal. Depending on the use case, buyers may need a newer locker terminal, different card readers, management software, network switching, or broader access-control project services. The options below help frame those decisions without assuming that every item is required.
ZKTeco LockerPad-G4 Pro
Consider a newer LockerPad family model when the project requires a different feature set, lifecycle position, biometric capability, or platform architecture. The exact decision should be based on current vendor specifications and project requirements rather than model age alone.
ZKTeco ProID Series readers
Useful when card verification is part of the locker workflow. Confirm credential frequency and format before reader selection.
ZKTeco QR600 / QR500 reader families
ZKTeco lists these reader families as compatible options around the LockerPad ecosystem. Confirm exact use, interface, credential workflow and current model compatibility for the selected deployment.
ZKBio CVSecurity
The management platform is central to locker allocation and administration. Licensing, server environment and deployment scope should be included in project planning.
Project network switching
A managed site may need network switching for terminals, controllers, cameras or other infrastructure. The locker terminal itself uses DC power, so PoE should not be assumed for this product.
Why buyers choose FourTeck for project guidance
Smart locker projects sit between access control, cabinet hardware, networking, software and facilities work. Buyers often need help defining what belongs on the quotation before they can compare suppliers. FourTeck’s role is to help structure that request around the real business requirement rather than treating the terminal as an isolated box.
Discuss current supply options and related components without assuming ready stock.
Translate locker count, user method, control boards and software into a clearer bill of materials.
Help separate hardware, accessories, licensing, installation and delivery scope for easier review.
Coordinate supply planning based on location, quantity, project timing and supplier availability.
Clarify warranty duration, covered items and handling expectations on the commercial offer.
Review readers, control components, network items and alternative models when the base terminal does not match the requirement.
This approach is especially useful for procurement teams that receive a model request from facilities or security staff but do not yet have a complete technical scope. Instead of issuing a purchase order against the terminal alone, the team can collect cabinet drawings, lock count, user volume, credential type, network availability, management requirements and service expectations first. FourTeck’s CCTV and access control solutions page provides broader context for integrated facility-security requirements.
Frequently asked questions
What is the LockerPad-7B used for?
It is used as the user-facing control terminal in an electronic locker system. It can verify users by face and supported cards, communicate with lock-control boards, and work with ZKBio CVSecurity for locker administration. Common applications include gyms, staff facilities, education spaces, public venues, shared storage and other sites where many users need controlled access to multiple cabinet doors.
Does the terminal include the locker cabinets?
No. ZKTeco’s regional product information explicitly notes that cabinets are not included. A complete project may require locker cabinets, electric locks, lock-control boards, power supplies, wiring, mounting hardware, card readers if needed, network connectivity, software, and installation services. Ask the supplier to list each included and excluded component so the quotation can be evaluated correctly.
How many locker doors can one terminal control?
ZKTeco publishes support for up to 96 cabinets by connecting as many as eight lock-control boards over RS485. Each control board provides twelve relay outputs. The practical design still depends on cabinet layout, lock type, wiring, power supplies and control-board placement, so a 96-door requirement should be reviewed as a complete electrical and cabinet integration project.
Can it work with employee cards as well as face recognition?
Yes, the published specification supports card verification through compatible external reader options. ZKTeco lists 125 kHz ID as standard and 13.56 MHz IC or multi-technology card modules as optional. Before ordering, confirm the exact credential technology used by your organization because card frequency and physical appearance alone do not guarantee that an existing badge will work with a selected reader.
What software is required for centralized management?
ZKTeco lists ZKBio CVSecurity as the supported management platform. It can be used to manage locker users, rights and cabinet status. Buyers should confirm the required software version, licensing, server environment, network reachability, administrator roles, backup policy and whether the locker module will operate alongside other ZKBio CVSecurity functions already deployed in the organization.
Is the ZKTeco LockerPad-7B available in Dubai or the UAE?
FourTeck can support UAE inquiries for the model, but current availability depends on supplier status, quantity, regional version, accessories and project timing. Contact FourTeck with the number of terminals and lockers, preferred authentication method, delivery location and target date. The team can review the requirement and provide current commercial guidance instead of relying on an unverified stock assumption.
What should I send to FourTeck for an accurate quote?
Send the product model, terminal quantity, locker-door count, user count, preferred face or card workflow, existing card type, lock model if already chosen, cabinet drawings if available, software requirement, network conditions, installation site, delivery location, target date and warranty expectations. If you need installation or commissioning, include that scope so the quotation separates product supply from project services.
Does it need wired networking?
The terminal supports TCP/IP networking and 2.4 GHz Wi-Fi, so the management connection can be planned around the site design. RS485 is used for the lock-control-board connection. For business deployments, wired Ethernet may still be preferred where consistent connectivity is important, but the final choice should consider cable routes, network security, reliability, IT policy and where the management server is located.
How do I choose between this model and another smart locker terminal?
Compare the number of cabinets, authentication methods, user capacity, software platform, interfaces, operating system lifecycle, environmental limits, available accessories and support requirements. A newer model may be preferable when it better matches current platform or biometric needs, while LockerPad-7B can remain suitable where its published architecture fits the project. FourTeck can review the requirement before model selection.
Need help sizing the complete smart locker system?
FourTeck can review the locker count, user workflow, reader requirement, ZKBio CVSecurity scope, control boards, power, network, quantity, delivery location and warranty expectations before preparing a quotation.
Share the model, number of locker doors, authentication method, quantity, site location, software requirement and target deployment date.





Reviews